TracePLOT TG-BOND Alumina GC Columns:
Na2SO4 and KCl Deactivation
Optimized for linear and quantitative analysis of polar unsaturated hydrocarbons
• Strong bonding to prevent particle generation suits these columns in valve-switching operations without damage to injection and detection systems from particle release
• Columns to which water has adsorbed may be regenerated to restore full effi ciency and selectivity
• Each column has been tested to ensure proper fi lm thickness (1,3-butadiene), selectivity (propadiene and methyl acetylene), resolution (trans-2-butene and 1-butene) and coating efficiency (1,3-butadiene)
Applications: C1-C5 hydrocarbons. Unsaturated hydrocarbon isomers
TracePLOT TG-BOND Msieve 5A GC Columns
Designed for separation of Ar/O2 and other permanent gases
• Specially designed coating and deactivation procedures for chromatographic effi ciency and the integrity of the coating porous layer
• Deactivation process yields a sharp peak for CO elution rather than the tailing commonly seen in other columns
• High retention of molecular sieve permits separation of permanent gases at temperatures above ambient
• Uniform particles remain adherent to the tubing even following continuous valve-cycling
Applications: Permanent gases. Refinery or Natural gases
TracePLOT TG-BOND Q GC Columns
Non-polar columns incorporating particles to the walls of the tubing for essentially no particle release
• Non-polar 100% divinyl benzene phase
• Particles incorporated to the walls of the tubing for essentially no particle release
Applications:C1 to C3 isomers and alkanes up to C12. Separation of CO2, methane and 02/N2/CO. Analysis of oxygenated compounds and solvents
TracePLOT TG-BOND Q+ GC Columns
Intermediate polarity columns incorporating particles to the walls of the tubing for essentially no particle release
• Intermediate polarity, porous divinyl benzene homopolymer
• Particles incorporated to the walls of the tubing for essentially no particle release
Applications: Separation of ethane, ethylene and acetylene to baseline
TracePLOT TG-BOND S GC Columns
Mid-polarity columns incorporating particles to the walls of the tubing for essentially no particle release
• Mid-polarity, divinylbenzene 4-vinylpyridine solid phase
• Particles incorporated to the walls of the tubing for essentially no particle release
Applications: Non-polar and polar compounds
TracePLOT TG-BOND U GC Columns
Polar columns incorporating particles to the walls of the tubing for essentially no particle release
• Polar, divinylbenzene ethylene glycol/dimethylacrylate phase
• Particles incorporated to the walls of the tubing for essentially no particle release
Applications: Analysis of polar and non-polar compounds
TracePLOT Particle Traps for GC Instruments
Provides a safeguard from dislodged particles entering the detector
• Provides a safeguard from dislodged particles entering the detector