TraceGOLD GC Columns
TraceGOLD GC columns offer you a leap forward in column performance delivering low bleed and superior inertness ideally suited to MS applications.
TraceGOLD TG-1MS GC Columns
Exceptionally low bleed for optimal signal-to-noise ratio, sensitivity and MS integrity
• Non-polar, 100% Methylpolysiloxane
• Equivalent to USP G2
Applications: Hydrocarbons, PCBs, Drugs of Abuse, Gasoline range organics (GRO), Refinery gases, Essential oils, Pesticides.
TraceGOLD TG-XLBMS GC Columns
General purpose columns exhibiting extremely low bleed
• Low polarity phase, proprietary
• Low bleed for excellent signal-to-noise ratio, sensitivity and mass spectral integrity
• Ideal for analysis of active, high molecular weight compounds with sensitive GC-MS systems
Applications: Pesticides, PCB congeners, PAHs, Aroclor mixes.
TraceGOLD TG-5MS GC Columns
The most widely used MS phase in gas chromatography
• Low polarity phase, 5% Phenyl Methylpolysiloxane
• Low bleed for excellent signal-to-noise ratio, sensitivity and mass spectral integrity
• Exceptional inertness ideal for analysis of active compounds
• Equivalent to USP G27 phase
Applications: Semi-volatiles, Phenols, Aminoes, Residual solvents and solvent impuritities, Drugs of abuse, Pesticides, PCB cogeners, Aroclor mixes.
TraceGOLD TG-SQC GC Columns
Ensure the quality of a Thermo Scientific instrument when installed on site
• Optimized for system qualifi cation tests for new GC-MS installations or during service/maintenance of an existing instrument
• We recommend reserving this column for benchmark testing only
Applications: System Qualification Tests (Thermo Scientific GC-MS)
TraceGOLD TG-5MS AMINE GC Columns
Analysis of ppm levels of amines without column priming
• Low polarity phase, base optimized 5% phenyl methylpolysiloxane
• Tubing surface is chemically altered to reduce tailing of active basic compounds
• Also allows analysis of neutral or weakly acidic compounds (e.g., phenols) and compounds susceptible to hydrogen bonding
• Low bleed at maximum operating temperature
Applications: Amine and other basic compounds, incluiding alkylamines, diamines, triamines, ethanolamines. Nitrogen - containing heterocyclis
TraceGOLD TG-5SilMS GC Columns
Incorporate phenyl groups in the polymer backbone for improved thermal stability, reduced bleed and reduced susceptibility to oxidation
• Low polarity, silarylene phase with selectivity comparable to 5% phenyl methylpolysiloxane
• Designed for low bleed and outstanding inertness
Applications: GC-MS applications using ion-trap systems, Polycyclic aromatics, Hydrocarbons including chlorinated hydrocarbons, Phthalates, Phenols, Amines, Organophosphate.
TraceGOLD TG-5HT GC Columns
Offers extended operation up to 400°C, ideal for high temperature extended GC applications
• Low polarity, 5% phenyl methylpolysiloxane phase
• Lower bleed and better inertness than comparable high-temperature columns
• Special design of fused silica tubing extends column lifetime by up to 40%
Applications: Phenols,Residual solvents, Solvents, Semivolatiles, Pesticides, PCBs, Solvent impurities.
TraceGOLD TG-35MS GC Columns
Higher phenyl content for useful elution order and retention time changes
• Mid-polarity phase, 35% phenyl methylpolysiloxane
• Equivalent to USP G42 phase
Applications: Organochlorine pesticides and herbicides, Pharmaceuticals, PCB cogeners, Aroclor mixes, Sterols, Rosin acids, Phthalate esters.
TraceGOLD TG-35MS AMINE GC Columns
Chemically altered tubing surface reduces tailing and eliminates the need for column priming
• Mid-polarity phase, base optimized 5% phenyl methylpolysiloxane
• Developed for analysis of active basic compounds without derivatization
• Also allows analysis of neutral compounds and adsorptive compounds with oxygen groups susceptible to hydrogen bonding
• Low bleed at maximum operating temperature
Applications: Amines including alkylamines, diamines, triamines and ethanolamines. Nitrogen-containing heterocyclics.
TraceGOLD TG-1301MS GC Columns
Low bleed, excellent reproducibility and column-to-column consistency even with sensitive detectors like ECD and MS
• Low to mid-polarity phase, 6% cyanopropylphenyl methylpolysiloxane
• Long lifetime
• Excellent inertness
• Equivalent to USP G43 phase
Applications: Alcohols, Volatile organics, Oxygenates, Residual solvents.
TraceGOLD TG-624 GC Columns
Offers 90+% resolution of the first six gases in EPA Method 8260 and EPA Method 524.2 for volatile organics analysis
• Low to mid-polarity phase, 6% cyanopropylphenyl methylpolysiloxane
• Ideal for EPA methods 624 and 608
• Allows resolution of 2-nitropropane from 1,1-dichloropropanone under EPA Method 524.2 revision IV
Applications: Residual solvents, Volatile Organic Compounds, Alcohols, Oxigenates.
TraceGOLD TG-624SilMS GC Columns
High thermal stability column ideal for volatile organics analysis
• Low to -mid polarity phase, 6% cyanopropylphenyl methylpolysiloxane
• High thermal stability – maximum temperatures up to 320°C
• Highly inert – excellent peak shape for a wide range of compounds
Applications: Residual solvents, Volatile Organic Compounds, Alcohols, Oxigenates.
TraceGOLD TG-VRX GC Columns
Application specific column for volatile organic pollutants
• Highly stable polymer phase
• Low bleed for excellent signal-to-noise ratio, sensitivity and mass spectral integrity
• Excellent resolution for analysis of volatile compounds
• Fast analysis times for volatile compounds
Applications: Volatile Organic pollutants. US EPA Method 8021 compounds